Single AC · 1.0 / 1.5 / 2.0 ton · September 2026

One AC is easy by day. One AC in load-shedding is a battery.

A 1.5-ton inverter AC draws about 1.0–1.3 kW once it is running. That is four to six 645 W plates for the sun, and two 5 kWh LFP packs if you want it at night. It is not two leftover plates and a tubular.

The two jobs

Say which hours. The BOM changes completely.

DAY AC

Office / shop, sun is up

PV covers the compressor while the feeder is live or during short afternoon shed if you have a hybrid + small LFP. No night AC. Cheapest honest “AC solar”.

1.5-ton: 5–6 × 645 W · 3.6–6 kW hybrid · 0–1 × 5 kWh LFP
Band ~Rs 4.5–7 lakh

NIGHT / SHED AC

House bedroom through WAPDA death

6 hours × 1.2 kW ≈ 7.2 kWh from the battery, plus inverter loss. That is two 5.12 kWh LFP packs (~9 kWh usable), not four tubulars (those are ~4.8 kWh usable and they hate AC cycling).

Same PV + 6–10 kW hybrid + 2 × 5 kWh LFP
Band ~Rs 9–13 lakh

Math

Running watts, not the 18,000 BTU sticker.

ACRunning W (inverter)Day 8 h energyPV at 0.78 derate, ~5 PSHPlates @ 645 WNight 6 h usable kWh
1.0 ton inverter~8506.8 kWh~1.7 kW3 (we spec 4)~5.1 kWh → 1–2 LFP
1.5 ton inverter~1,2009.6 kWh~2.5 kW4 (we spec 5–6)~7.2 kWh → 2 LFP
2.0 ton inverter~1,60012.8 kWh~3.3 kW6 (we spec 7–8)~9.6 kWh → 2–3 LFP

Headroom is for heat, dirty filters, long lines, and the second fan in the same room. Non-inverter / “conventional” ACs punch 3× on start — we will not hang those on a small hybrid.

What shops get wrong

If the kit cannot name the hours, walk away.

12 V “AC solar kit”

A car-style inverter and one 200 Ah tubular will not run a 1.5-ton. It will click, dip, and kill the compressor warranty.

Two plates + 3 kW UPS

That is a fan system with an AC sticker. Day AC needs ~2.5 kW of real PV after derate, which is five 645 W modules, not two 540 W leftovers.

Tubular for night AC

Four 200 Ah at 50% DoD ≈ 4.8 kWh usable. A 1.5-ton wants ~7 kWh. The bank hits empty and the AC dies at 1 a.m. LFP or don’t promise it.

Add fans and lights on the same box

A single-AC hybrid can carry 2–3 fans and LEDs without drama. Fridge too, if you sized the LFP. Geyser and a second AC cannot.

Growing into a house system

If you will add a fridge and more rooms this year, start at the home hybrid (6 kW / 10 plates) and put the AC on the backup port. Cheaper than buying a 3.5 kW kit twice.

Single-AC load preset If you only need fans LFP sizes